DTC-1200-141EMKS

DTC-1200-141EMKS
Click image for Gallery
  • Цена: 200.00лв
+
-

Temperature Difference Controller (Wall Type)

This instrument is designed to control the circulation pump according to the temperature difference (collector temperature-return temperature) in water heating applications with solar power.

Process Input: 2 x PTC or 2 x PT-1000
2 sensor inputs for Collector and Return
(should be described while ordering)

Accuracy: %1 , Measurement Interval

Resolution: 1 °C

Other Features:Display Selections:
   Collector Temperature
   Return Temperature
   Collector and Return Temperature Difference
Avavilability of defining temperature difference for circulation pump when active and inactive in cycle
Collector Freezing Protection
SDetermination of Output location when sensor is broken off (ON, OFF or PERIODICAL working)
Program Input Lock
Programming and Changing Temperature Difference Set Value easily on front panel

Работно напрежение 230V AC
Работна честота 50-60Hz
Изходни контакти Relay (8A@250Vac)or SSR Driver Output
Дисплей 4 digit LED display, 10mm
Термодвойка PTC
Температурно измерване -50...150°C
Размери 75 x 115 mm